Sensor Installation and Connection 3-45

Standard Mount

Mount the Surface Combo Sensor or the Ultrasonic Depth Sensor
using this method in the following way:

Note: Handle the sensor with care, and do not expose it
to extreme temperatures for an extended period of time.
Keep the sensor in its protective packaging until it is time
for installation. Avoid contacting the metal connector at
the end of the Surface Combo Sensor cable with the
Teflon-coated crystals on the sensor.

1. Position the Surface Combo Sensor/Ultrasonic Depth Sensor

mounting plate in the center apex of the pipe, and scribe a
mark on both sides of the mounting plate.

2. Center the 305-mm mounting band, allowing the band to

extend about 102 mm beyond each side of the scribed location.

3. Conform one end of the curved band to the pipe configuration,

and spot drill to mark the bolt location.

4. Remove the curved band, drill an anchor bolt hole, and gently

tap an M6 x 55-mm anchor bolt into the hole.

5. Mount the curved band to the anchor bolt through the pre-

drilled hole on the band, and hand-tighten a nut with washer to
the anchor bolt to secure the band.