3-38 IETG FlowHawk Manual

Mounting Peak Combo Sensors and Slimline Peak
Combo Sensors

Two special installation methods are available for mounting the
Peak Combo Sensor and Slimline Peak Combo Sensor.

¾-band mount

½-band mount

Both mounts require almost identical installation methods. The
only significant differences are that the ¾-band mount allows the
installer to secure the band to both sides of the pipe wall and to
position the sensor at the bottom center of the pipe. These options
are not possible using the ½-band mount. Therefore, the ¾-band
mount is the preferable method for mounting the sensors.

However, a ½-band mount may be appropriate for monitoring
under the following circumstances:

Large pipes with deep minimum flows

Large pipes with excessive silt present

½- (left) and ¾-band (right) mounts

Note: When positioning the special mounting metal,
remember the 15

°

offset limitation on the Peak Combo

Sensor/Slimline Peak Combo Sensor.