Sensor Installation and Connection 3-23

Mounting the Peak Combo Sensor or Slimline
Peak Combo Sensor

Mount the Peak Combo Sensor or Slimline Peak Combo Sensor to
the ring in the following way:

1. Use two M3 X10-mm stainless steel flathead screws (do not

substitute any other screws) to mount the sensor at the bottom
of the ring (opposite the Surface Combo Sensor/Ultrasonic
Depth Sensor) with the tapered end of the sensor facing
upstream.

2. Orient the ring so that the Surface Combo Sensor/Ultrasonic

Depth Sensor is directly on top. If a sensor is not in use at the
top of the pipe, make sure the spreader assembly is directly at
the top.

3. Secure the sensor cable to the ring. Refer to Securing the

Cables to the Ring on page 3-24 for instructions on properly
securing the cable.

Mounting the Peak Combo Sensor or Slimline Peak Combo Sensor to the

ring

Advertising