Sensor Installation and Connection 3-49

SURFACE COMBO SENSOR

SENSOR MOUNTING PLATE

Fastening the Surface Combo Sensor to the mounting plate on the band

Note: Remember, this new (available late 2012) version
of the Surface Combo Sensor (p/n 8K-CS5-V2-XX-30)
includes a different mounting plate and involves a slightly
different installation procedure, as described in this
manual, than the existing Surface Combo Sensor (p/n 8K-
CS3-V2-XX-30). To install the existing version of the
sensor onto the mounting plate, refer to the instructions
below for the Ultrasonic Depth Sensor.

Ultrasonic Depth Sensor Slide the Ultrasonic Depth

Sensor into position from the upstream end of the
mounting plate until the back of the sensor comes in
contact with the backstop.