6-22 IETG FlowHawk Manual

Edit the following Device Parameters at the bottom of the dialog,
and then edit the individual tabs as described in the following
sections.

Physical Offset Enter the physical offset for the sensor at
the time of installation if it was installed offset from the bottom
center of the pipe. Refer to Chapter 3, Sensor Installation and
Connection, for instructions on measuring the physical offset.

The default physical offset is 0.

Channel Select the channel number of the port on top of the
monitor to which the device is connected.

Pipe Height This field displays the pipe height at the
monitoring point, based on the installation table. This
parameter is not editable from this location.

Note: Under normal conditions, the remaining parameters
corresponding to the Peak Combo and Peak Combo SL
devices
should not require modification. However, if
additional adjustments are necessary, the following
sections provide a detailed description of each parameter.

Ultrasonic tab

Edit the following parameters corresponding to the upward-looking
ultrasonic depth sensor in the Peak Combo Sensor/Slimline Peak
Combo Sensor (i.e., the Peak Combo SL device):

Enable Select this checkbox to ensure the monitor begins
taking upward ultrasonic depth readings at the designated
interval upon activation.

Flow Type Select the option that best reflects the kind of
flow conditions that typically occur at the monitoring point
from the drop-down list:

Typical Flow exhibits a typical diurnal pattern. This is

the default setting.

Wet/Stagnant Flow remains in the pipe, but moves only

during wet weather events.