6-8 IETG FlowHawk Manual

transfer), and most countries are phasing out CSD
services. Therefore, ADS strongly discourages using this
communication option with the FlowHawk.

Serial Choose this option for direct, on-site

communication.

7. Enter the monitor’s Serial Number.

8. Choose one of the following methods for collecting data using

Profile:

Auto Collection Select the Autocollect checkbox to

ensure Profile collects the data for the period from the last
timestamp or a user-defined start date and time to the
current date and time. Edit the corresponding Start Time
date and time to initiate auto collection at a user-defined
starting time.

Manual Collection Edit the Start time and End time

fields to designate the date and time period for which you
want Profile to collect data from the monitor.

Note: The date and time range displayed in the Monitor
Data
section represent the total range of data available in
the monitor memory.

9. Enter the number of hours difference between the your location

(or the location of the computer on which the database resides)
and the location of the monitor in the Time Zone field. For
example, if you are in the U.S. Central time zone and the
monitor is located in the U.S. Eastern time zone, enter 1 in this
field. If you are in the Central time zone and the monitor is
located in the Pacific time zone, enter -2 in this field.

10. (optional) Enter the vertical distance from the manhole rim to

the bottom of the manhole invert in the Manhole Depth field.

11. Choose the rates at which you want the monitor to log data

from the corresponding drop-down lists:

Normal Select the standard rate at which you want the
monitor to store data.