3-58 IETG FlowHawk Manual

7. Seal any unused connectors with a cap. If necessary, obtain

additional caps from IETG.

Note: An air valve is present in the monitor top. This
valve exists only for testing purposes during the
manufacturing process. Do not attempt to fill the monitor
with air or pressurize the monitor!

Securing the Dryer Tube to the Monitor

The Peak Combo Sensor, Surface Combo Sensor, and Ultrasonic
Depth Sensor with the Pressure Option each contain a pressure
depth sensor with an associated dryer tube. For each combo sensor
connected to the monitor, you must secure the corresponding dryer
tube (attached to a cable running from the sensor connector) to the
monitor in the following way:

1. Attach the dryer tube from the pressure depth sensor in the

vertical position to the monitor handle using cable ties. Make
sure the clear, flexible tubing coming from the sensor
connector the top of the dryer tube is not kinked. If necessary,
use a loose cable tie to hold it in an unkinked position.

Securing the dryer tube to the monitor using cable ties

2. Make sure the black end cap on the dryer tube is removed

before installing the monitor in the manhole.