4-38

IETG FlowHawk Manual

Communication cable from EMU connected to monitor with stretch tape

properly applied

4. Run and connect the external power cable to the power supply,

and then connect to the power source. Refer to Chapter 5,
External Power, for information and instructions on installing
the power supply and connecting to the power source.

5. Contact a remote support analyst (with access to the Internet

and the Profile or Qstart software). Provide the IP address and
site name and then have the analyst attempt to communicate
with the flow monitor and perform standard diagnostics or
collect data.

6. Have the analyst verify the signal strength of the antenna is

higher than –85. Valid signal strength can range from –111 to
–51, with –51 being the highest/best possible signal strength
and –111 the lowest/worst possible signal strength. A signal
strength of less than –90 is considered poor and will result in
poor communication and a higher power drain. It also is likely
to have a negative impact during both data collection and
monitor configuration.