Configuration and Activation 6-57

monitor to calculate QContinuity. Edit the flow device in the
following way:

Flow Type Select QContinuity from the drop-down list.

Note: The options available for Depth Type and
Velocity Type correspond to the devices assigned to the
monitoring point.

Depth Type Select the depth sensor from which you want to
apply depth data in calculating QContinuity from the drop-
down list.

Velocity Type Select the velocity sensor from which you
want to apply velocity data in calculating QContinuity from the
drop-down list.

Store Data Select this checkbox to ensure the monitor stores
the flow data to memory.

Editing the MLI Device

Typically, the MLI device does not require editing. However, if the
monitor will support activities such as event notification or dual
data rates, refer to the Profile User’s Guide #950015 (version B4 or
higher) for detailed instructions on properly setting the applicable
parameters for the MLI device.