Register addresses for monitor information – ADS Environmental Services IETG FlowHawk QR 775012 A4 User Manual

Page 377

Advertising
background image

Modbus/EMUX Configuration and Diagnostics

D-9

Description

Profile Entity

Standard Units of

Measure

Registers

Flow rate based
on QContinuity

FLOW1

Litres per Second

40024-40025

(40088-40089)

Second Flow
rate based on
QContinuity

FLOW2

Litres per Second

40026-40027

40090-40091)

Peak Velocity
from the monitor

RAWVEL

Meters Per Second

40028-40029

(40092-40093)

Monitor Battery
Voltage (daily)

BTYVOLT

Volts

40030-40031

(40094-40095)

Flow Rate
Threshold from
monitor

QTHRESHOLD

Litres per Second

40032-40033

(40096-40097)

Average Flow
Rate from
monitor

QMLI_AVG

Litres per Second

40034-40035

(40098-40099)

Average Flow
Depth from
monitor

DMLI_AVG

Millimeters

40036-40037

(40100-40101)

Depth Threshold
from monitor

DTHRESHOLD

Millimeters

40038-40039

(40102-40103)

Pressure Sensor
Calibration Value

PRESSK

n/a

40040-40041

(40104-40105)

Unidepth

UNIDEPTH

Millimeters

(40108-40109)

Register Addresses for Monitor Information

The following table contains registers corresponding to more
general monitor information:

Description

Standard Units of Measure

Registers

Current Monitor Time

n/a

40128-40129

Last Monitor Scan Time

n/a

40130-40131