Configuration and Activation 6-29

second (mps) on a regular basis, ADS recommends choosing
the 4.572 mps option for this parameter.

Transmit Frequency Select the frequency at which to
transmit the signal. IETG recommends leaving the default
setting (Normal) for older Peak Combo Sensors (serial
numbers of 8xxxx) and selecting the High setting for newer
Peak Combo Sensors (serial numbers of 1xxx) and existing
Slimline Peak Combo Sensors. However, if hydraulic
conditions at the site are resulting in questionable or erroneous
readings, consider applying the other frequency option.
Contact IETG for assistance when necessary.

Gain This value represents the factor applied to raw velocity
(RAWVEL entity in Profile) to determine average velocity
(VELOCITY entity in Profile) and to calculate quantity for
typical daily flows. Profile does not apply the Gain to the
velocity readings reported in Diagnostics, where the raw
velocity readings are used for comparison against the manual
measurements. This parameter is editable through the
Installation Generator and the Quantity Coefficient
Generator
in Profile.

Cross Check Gain Enter the value by which to multiply raw
velocity readings in the monitor to determine average velocity
for comparison purposes in the monitor.

Store Data Select this checkbox to ensure the monitor logs
the velocity data to memory. This option is selected by default.

Advanced Select this button to access the Advanced
Parameters
dialog.