Sensor Installation and Connection 3-43

Note: This value will be necessary when configuring the
monitor using the Profile or Qstart software.

12. Run the sensor cables from the sensor location in the pipe to

the monitor location in the manhole according to the
instructions in Securing the Sensor Cables in the Pipe and
Manhole
on page 3-53.

Note: If the pipe is large and the sensor cable cannot
reach the pipe crown, attach the sensor cables to 12-mm
PVC tubing and anchor the tubing to the wall. This will
help prevent sensor damage during heavy flow.

Securing the Cables to the Band

Securing the Peak Combo Sensor or Slimline Peak Combo Sensor
cable to the band helps prevent debris from collecting between the
cable and the band or catching on the loose cable. It also prevents
the loose cables from disrupting the flow.

Secure the cable in the following way:

1. Starting at the appropriate sensor location, begin securing the

sensor cable with 2-mm x 100-mm cable ties through the pre-
drilled holes along the downstream (trailing) edge of the band
up the side of the band. Run the cable up the right side of the
band (on the downstream edge of the band).

Sensor cabling