3-28 IETG FlowHawk Manual

Notice how the elevated sensor provides a gap in which debris can collect

Notice how deterioration in the pipe surface creates a space for debris to

collect under the sensor

4. Expand the ring by turning the spreader mechanism nut

counter-clockwise with the crank handle or socket. However,
do not tighten the ring against the pipe completely at this point.

5. Mount the Surface Combo Sensor or Ultrasonic Depth Sensor

to the ring in the following way based on the sensor type:

Surface Combo Sensor Mount this sensor by

inserting the studs on the back of the sensor into the
keyholes on the sensor mounting plate (at the top of the
ring) and sliding the sensor back (in a downstream
direction) until it is fully in place. The sensor cable should
exit the downstream edge of the ring. Orient the sensor

Advertising