Ultrasonic Depth Subsystem

The following tables contain general troubleshooting techniques for
problems with the ultrasonic depth subsystem corresponding to the
Surface Combo Sensor and the Ultrasonic Depth Sensor.

Note: Contact your IETG representative for further
diagnosis prior to replacing a sensor.

Problem

Range from ultrasonic depth subsystem is slightly
inconsistent with manually measured range.

Possible

Causes

Physical offset may be incorrect.

Pipe height may be incorrect.

Electronic offset might be incorrect.

Possible

Solutions

Verify the physical offset, and adjust it if necessary.

Verify the pipe height.

Verify electronic offset and adjust if necessary.