Description:

This function processes an AUX channel request issued by the connected DisplayPort

source.

cmd

and

address

are the command byte and the address in the original request

received, respectively (refer to the DisplayPort specification for more details). When

the request is a write,

data

must point to the data bytes sent by the source. To support

address-only requests,

length

is the original

len

byte sent by the source incremented

by one. When the request is a read,

data

is not used and can be NULL.

This function provides all the functionality of the DPCD registers implemented inside

the system library, including:
• DPCD locations read/write support

• EDID read support

• Link training execution

• Forwarding of AUX channel replies back to the source

Example:

btc_dprx_aux_handler(0, pcmd, padd, plen, pwrdata);

Related Information

btc_dprx_aux_get_request

on page 8-3

btc_dprx_aux_post_reply

Prototype:

int btc_dprx_aux_post_reply(
BYTE rx_idx
BYTE cmd,
BYTE size,
BYTE *data)

Thread-safe:

Yes

Available from

ISR:

Yes

Include:

<

btc_dprx_syslib.h

>

Return:

0 = success, 1 = fail

Parameters:

rx_idx

—Sink instance index (0 - 3)

cmd—

Command

size

—Number of data bytes transmitted (0 - 16)

data—

Pointer to data transmitted

UG-01131