Contrastthreshold – Adept AdeptSight Reference Guide User Manual

Page 140

Advertising
background image

ContrastThreshold

VPARAMETER

303

Defines the minimum contrast needed for an edge to be detected in the input image and used for arc

computation. This threshold is expressed in terms of a step in greylevel values. The property is read only

except when ContrastThresholdMode is set to hsContrastThresholdFixedValue.

Syntax

Micro V+

VPARAMETER (sequence_id, tool_id, 303, index_id, object_id) = value

value = VPARAMETER (sequence_id, tool_id, 303, index_id, object_id)

V+

VPARAMETER (sequence_id, tool_id, 303, index_id, object_id) $ip = value

value = VPARAMETER ($ip, sequence_id, tool_id, 303, index_id, object_id)

Type

Long

Range

Minimum: 1

Maximum: 255

Remark(s)

By default, the tool selects a ContrastThresholdMode based on image content to provide flexibility to

variations in image lighting conditions and contrast. Adaptive threshold modes are generally

recommended. A fixed-value contrast threshold should only be used when adaptive values do not

provide satisfactory results.

Parameters

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard IP

address format, for example: 192.168.1.120.

ContrastThreshold

AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012

Page 140

Advertising