Defaultconformitytolerance – Adept AdeptSight Reference Guide User Manual

Page 146

Advertising
background image

DefaultConformityTolerance

VPARAMETER

552

Default value for ConformityTolerance computed by the Locator by analyzing the calibration, the contour

detection parameters, and the search parameters. Read only.

Syntax

MicroV+

value = VPARAMETER (sequence_id, tool_id, 552, index_id, object_id)

V+

value = VPARAMETER ($ip, sequence_id, tool_id, 552, index_id, object_id)

Remarks

This default value is used for ConformityTolerance when UseDefaultConformityTolerance is set to True.

Type

Double

Range

Greater than 0.

Parameters

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard IP

address format, for example: 192.168.1.120.

sequence_id

Index of the vision sequence. The first sequence is 1.

tool_id

Index of the tool in the vision sequence. The first tool is 1.

ID

552: the value used to reference this property.

index_id

N/A

object_id

N/A

Related Properties

DefaultConformityTolerance

AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012

Page 146

Advertising