Showresultsgraphics – Adept AdeptSight Reference Guide User Manual

Page 461

Advertising
background image

ShowResultsGraphics

VPARAMETER

150

When enabled, vision results are displayed in the image display control. When disabled, vision results are

not displayed.

Syntax

Micro V+

VPARAMETER (sequence_id, tool_id, 150, index_id, object_id) = value

value = VPARAMETER (sequence_id, tool_id, 150, index_id, object_id)

V+

VPARAMETER (sequence_id, tool_id, 150, index_id, object_id) $ip = value

value = VPARAMETER ($ip, sequence_id, tool_id, 150, index_id, object_id)

Type

Boolean

Range

Value

Description

1

Enabled: Vision results are displayed in the image display control.

0

Disabled: Vision results are not displayed.

Parameters

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard IP

address format, for example: 192.168.1.120.

sequence_id

Index of the vision sequence. The first sequence is 1.

tool_id

Index of the tool in the vision sequence. The first tool is 1.

ID

150: the value used to reference this property.

index_id

N/A

object_id

N/A

ShowResultsGraphics

AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012

Page 461

Advertising