MeasurementPointsCount

VRESULT

2002

The number of points where the local sharpness is evaluated. When the Image Sharpness tool is executed,

it scans the region of interest and identifies a number of candidate locations (equal to

CandidatePointsCount) where the local standard deviation is the highest. The local sharpness is then

evaluated at each of the candidate locations that has a local standard deviation above

StandardDeviationThreshold. Read only.

Syntax

Micro V+

value = VRESULT (sequence_id, tool_id, instance_id, 2002, index_id, frame_id)

V+

value = VRESULT ($ip, sequence_id, tool_id, instance_id, 2002, index_id, frame_id)

Type

Long

Range

Minimum: 0

Maximum: CandidatePointsCount

Parameters

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard IP

address format, for example: 192.168.1.120.

sequence_id

Index of the vision sequence. The first sequence is 1.

tool_id

Index of the tool in the vision sequence. The first tool is 1.

ID

2002: the value used to reference this property.

index_id

N/A

object_id

N/A