FilterHueTolerance

VPARAMETER

5716

Value of the tolerance allowed for Hue value defined by FilterHueValue, for the selected filter. The

FilterHueTolerance value is distributed equally above and below the FilterHueValue.

For example, if FilterLuminanceValue = 200 and FilterHueTolerance = 20, the filter will accept pixels

with a range of hue values = [190,200].

Syntax

Micro V+

VPARAMETER (sequence_id, tool_id, 5716, filter_id, object_id) = value

value = VPARAMETER (sequence_id, tool_id, 5716, filter_id, object_id)

V+

VPARAMETER (sequence_id, tool_id, 5716, filter_id, object_id) $ip = value

value = VPARAMETER ($ip, sequence_id, tool_id, 5716, filter_id, object_id)

Remarks

When FilterHueTolerance = 1, no tolerance (variation) in luminance is accepted. The filter will only

accept pixels with a luminance value equal to FilterHueValue.

Type

Long

Range

Minimum: 1

Maximum: 128