Filterluminancetolerance – Adept AdeptSight Reference Guide User Manual

Page 210

Advertising
background image

FilterLuminanceTolerance

VPARAMETER

5718

Value of the tolerance allowed for Luminance value defined by FilterLuminanceValue, for the selected

filter. The FilterLuminanceTolerance value is distributed equally above and below the

FilterLuminanceValue.

For example, if FilterLuminanceValue = 200 and FilterLuminanceTolerance = 20, the filter will accept

pixels within a range of luminance values = [190,200].

Syntax

Micro V+

VPARAMETER (sequence_id, tool_id, 5718, filter_id, object_id) = value

value = VPARAMETER (sequence_id, tool_id, 5718, filter_id, object_id)

V+

VPARAMETER (sequence_id, tool_id, 5718, filter_id, object_id) $ip = value

value = VPARAMETER ($ip, sequence_id, tool_id, 5718, filter_id, object_id)

Remarks

When FilterLuminanceTolerance = 1, no tolerance (variation) in luminance is accepted. The filter

will only accept pixels with a luminance value equal to FilterLuminanceValue.

Type

Long

Range

Minimum: 1

Maximum: 128

Parameters

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard IP

address format, for example: 192.168.1.120.

FilterLuminanceTolerance

AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012

Page 210

Advertising