ModelDisambiguationEnabled

VPARAMETER

403

When set to True (default), the Locator applies disambiguation to discriminate between similar models and

between similar hypotheses of a single object. When set to False, the Locator does not apply

disambiguation.

Syntax

MicroV+

VPARAMETER (sequence_id, tool_id, 403, index_id, object_id) = value

value = VPARAMETER (sequence_id, tool_id, 403, index_id, object_id)

V+

VPARAMETER (sequence_id, tool_id, 403, index_id, object_id) $ip = value

value = VPARAMETER ($ip, sequence_id, tool_id, 403, index_id, object_id)

Type

Boolean

Range

Value

Description

1

Locator applies disambiguation.

0

Locator does not apply disambiguation.

Parameters

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard IP

address format, for example: 192.168.1.120.

sequence_id

Index of the vision sequence. The first sequence is 1.

tool_id

Index of the tool in the vision sequence. The first tool is 1.