Beltcalibrationscale – Adept AdeptSight Reference Guide User Manual

Page 66

Advertising
background image

BeltCalibrationScale

VPARAMETER

10004

The scale factor between encoder counts and millimeters, which is defined during the Belt Calibration. This

is the number of millimeters that the belt advances for each encoder count. Read only.

Syntax

V+

value = VPARAMETER (

$ip

, sequence_id, tool_id, 10004, index_id, object_id)

MicroV+

Not applicable. Conveyor-tracking is supported only in V+ running on the Adept Smart-

Controller.

Type

Double

Parameters

sequence_id

Must be set to -1.

tool_id

The camera number referenced in the keyword mapping of the camera calibration

object.

ID

10004: the value used to reference this property.

index_id

N/A

object_id

The robot number associated with the calibration.

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard IP address

format, for example: 192.168.1.120.

BeltCalibrationScale

AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012

Page 66