ContrastThresholdMode

VPARAMETER

302

Selects the method used to compute the threshold used for detecting edges in the input image.

Syntax

Micro V+

VPARAMETER (sequence_id, tool_id, 302, index_id, object_id) = value

value = VPARAMETER (sequence_id, tool_id, 302, index_id, object_id)

V+

VPARAMETER (sequence_id, tool_id, 302, index_id, object_id) $ip = value

value = VPARAMETER ($ip, sequence_id, tool_id, 302, index_id, object_id)

Type

Long

Remarks

By default, the tool selects a ContrastThresholdMode based on image content to provide flexibility to

variations in image lighting conditions and contrast. Adaptive threshold modes are generally

recommended. A fixed-value contrast threshold should only be used when adaptive values do not

provide satisfactory results.

Range

The valid range for this property is as follows:

Value Contrast Threshold Mode Name

Description

0

hsContrastThresholdAdaptiveLowSensitivity

Uses a low sensitivity adaptive threshold for
detecting edges. Adaptive Low Sensitivity
reduces the amount of noisy edges but may
also cause significant edges to be unde-
tected.

1

hsCon-
trastThresholdAdaptiveNormalSensitivity

Uses a normal sensitivity adaptive thresh-
old for detecting edges.

ContrastThresholdMode