VRESULT

1508

Range of greylevel values of the pixels in the tool's region of interest that are included in the final

histogram. Pixels removed from the histogram by tails or thresholds are not included in this calculation.

The range is equal to MaximumGreylevelValue - MinimumGreylevelValue + 1. Read only.

Syntax

Micro V+

value = VRESULT (sequence_id, tool_id, instance_id, 1508, index_id, frame_id)

V+

value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1508, index_id, frame_id)

Type

Long

Range

Minimum: 0

Maximum: 256

Parameters

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard

IP address format, for example: 192.168.1.120.

sequence_id

Index of the vision sequence. The first sequence is 1.

tool_id

Index of the tool in the vision sequence. The first tool is 1.

instance_id

Index of the instance for which you want the result.

ID

1508: the value used to reference this property.

index_id

The index of the frame for which you want to set the mode.

frame_id

N/A