SearchMode

VPARAMETER

5101

Specifies the method used by a Finder tool to select a hypothesis.

Type

Long

Range

The range depends on the type of entity. For arcs (Arc Finder Tool), the range is:

Value

Description

0

hsBestArc

Selects the best arc according to hypothesis strength.

1

hsArcClosestToGuideline

Selects the arc hypothesis closest to the Guideline.

2

hsArcClosestToInside

Selects the arc hypothesis closest to the inside of the
tool Search Area. (closest to the tool center).

3

hsArcClosestToOutside

Selects the arc hypothesis closest to the outside of the
tool Search Area. (furthest from the tool center)

For lines (Line Finder Tool), the range is:

Value

Description

0

hsBestLine

Selects the best line according to hypothesis
strength.

1

hsLineClosestToGuideline

Selects the line hypothesis closest to the Guideline.

2

hsLine-
WithMaximumNegativeXOffset

Selects the line hypothesis closest to the Search
Area bound that is at maximum negative X offset.

3

hsLine-
WithMaximumPositiveXOffset

Selects the line hypothesis closest to the Search
Area bound that is at maximum positive X offset.

For points (Point Finder Tool), the range is:

SearchMode