V+

value = VRESULT ($ip, sequence_id, tool_id, instance_id, 2701, index_id)

Type

Long

Parameters

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard IP

address format, for example: 192.168.1.120.

sequence_id

Index of the vision sequence. The first sequence is 1.

tool_id

Index of the tool in the vision sequence. The first tool is 1.

instance_id

Index of the instance for which you want the result.

ID

2701: the value used to reference this property.

index_id

The filter index you want returned.

InspectionFilterPassStatus

VRESULT

2702

The code returns the pass status of the specified filter for the instance. Read only.

Syntax

Micro V+

value = VRESULT (sequence_id, tool_id, instance_id, 2702, index_id)

V+

value = VRESULT ($ip, sequence_id, tool_id, instance_id, 2702, index_id)

Type

Long

Parameters