Blobelongation – Adept AdeptSight Reference Guide User Manual

Page 89

Advertising
background image

BlobElongation

VRESULT

1616

Ratio of the moment of inertia about the blob’s minor axis (BlobInertiaMaximum) to the moment of inertia

about the blob’s major axis (BlobInertiaMinimum). Read only.

Syntax

Micro V+

value = VRESULT (sequence_id, tool_id, instance_id, 1616, index_id, frame_id)

V+

value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1616, index_id, frame_id)

Remarks

No units.

Type

Double

Range

Boundaries of the input image.

Parameters

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard IP

address format, for example: 192.168.1.120.

sequence_id

Index of the vision sequence. The first sequence is 1.

tool_id

Index of the tool in the vision sequence. The first tool is 1.

instance_id

Index of the blob for which you want the result.

ID

1616: the value used to reference this property.

index_id

N/A

frame_id

Frame containing the blob for which you want the result.

BlobElongation

AdeptSight Reference Guide, v3.2.x, Updated: 5/8/2012

Page 89