InstanceMatchQuality

VRESULT

1318

Amount of matched model contours for the selected object instance. Match quality ranges from 0 to 1,

with 1 being the best quality. A value of 1 means that 100% of the model contours were successfully

matched to the actual contours detected in the input image. Read only.

Syntax

MicroV+

value = VRESULT (sequence_id, tool_id, instance_id, 1318, index_id, frame_id)

V+

value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1318, index_id, frame_id)

Remarks

Index of frame that contains the specified instance. Range: [1, ResultCount -1]

Type

Double

Range

Minimum: 0.0

Maximum: 1.0

Parameters

sequence_id

Index of the vision sequence. The first sequence is 1.

tool_id

Index of the tool in the vision sequence. The first tool is 1.

instance_id

Index of the instance for which you want the result.

ID

1318: the value used to reference this property.

index_id

N/A

frame_id

Index of frame that contains the specified instance.

InstanceMatchQuality