MaximumInstanceCountEnabled

VPARAMETER

518

When MaximumInstanceCountEnabled is True, the search is limited to the number of instances set by

the MaximumInstanceCount property

Syntax

MicroV+

VPARAMETER (sequence_id, tool_id, 518, index_id, object_id) = value

value = VPARAMETER (sequence_id, tool_id, 518, index_id, object_id)

V+

VPARAMETER (sequence_id, tool_id, 518, index_id, object_id) $ip = value

value = VPARAMETER ($ip, sequence_id, tool_id, 518, index_id, object_id)

Type

Long

Range

Value

Description

1

Search is limited to number of instances specified by MaximumInstanceCount.

0

Search is not limited to a set number of instances.

Parameters

sequence_id

Index of the vision sequence. The first sequence is 1.

tool_id

Index of the tool in the vision sequence. The first tool is 1.

ID

518: the value used to reference this property.

index_id

N/A

object_id

N/A

$ip

IP address of the vision server. Applies to V+ syntax only. Uses standard IP

address format, for example: 192.168.1.120.