82

Chapter 8, Using Matrox MXO2 with Adobe Premiere Pro

¦

Note

The higher the DC precision value that’s used to capture or render

your video, the more likely that the DC content will be increased at the expense
of the AC content in the encoded stream. This may result in lowering the
overall quality of the compressed stream at a specified data rate.

6

Under

Zig Zag Type

, select one of the following:

$

Regular

Sets the regular (default) zig zag scanning pattern of the AC

coefficient of the DCT block as defined in the ISO/IEC 13818-2 (figure
7-2) specification documentation.

$

Alternate

Sets an alternate zig zag scanning pattern of the AC

coefficient of the DCT block as defined in the ISO/IEC 13818-2 (figure
7-3) specification documentation. Use this setting when capturing or
rendering video at a high data rate (that is, at a data rate of about 50
Mb/sec for SD video, or 100 Mb/sec or higher for HD video).

7

Select the

Force Frame-based DCT

setting to render macroblocks as

frames rather than as fields. In some cases, graphics will yield less artifacts if
this option is selected.

8

Click

OK

to save your settings.