CPIndex - This command configures queue number of sampled packet.

Q_No - This command sets congestion point index.

Default Setting

0

Command Mode

Global Config

7.2.18.8 congestion-notify outer

This command set value of CNM's outer VLAN tag's CFI bits, value of CNM's outer VLAN tag's 802.1p
bits, value of CNM's outer VLAN tag's TPID, and set the CNM's outer VLAN ID.

Syntax

congestion-notify outer { CFI <-1-1> | Dot1p <-1-7> | TPID <0-65535> | vlan <0-4095>}

no congestion-notify outer { CFI | Dot1p | TPID| vlan}

<-1-1> - This command sets value of CNM's outer VLAN tag's CFI bits.

<-1-7> - This command sets value of CNM's outer VLAN tag's 802.1p bits.

<0-65535> - This command sets value of CNM's outer VLAN tag's TPID.

<0-4095> - This command sets the CNM's outer VLAN ID.

no - This command restored default value.

Default Setting

Command Mode

Global Config

7.2.18.9 congestion-notify inner

This command set value of CNM's inner VLAN tag's CFI bits and value of CNM's inner VLAN tag's
802.1p bits.

Syntax

congestion-notify inner { CFI <-1-1> | Dot1p <-1-7>}

no congestion-notify inner { CFI | Dot1p}