unknown(6) - Unknown status.

Last Updated - The last sysUpTime that this neighbor has been updated.

Command Buttons

Refresh - Refresh the data on the screen with the present state of the data in the router.

11.2.3.6 HTTP Configuration

Configurable Data

HTTP Session Soft Timeout - This field is used to set the inactivity timeout for HTTP sessions. The
value must be in the range of (0 to 60) minutes. A value of zero corresponds to an infinite timeout.
The default value is 5 minutes. The currently configured value is shown when the web page is
displayed.

HTTP Session Hard Timeout - This field is used to set the hard timeout for HTTP sessions. This
timeout is unaffected by the activity level of the session. The value must be in the range of (0 to 168)
hours. A value of zero corresponds to an infinite timeout. The default value is 24 hours. The currently
configured value is shown when the web page is displayed.

Maximum Number of HTTP Sessions - This field is used to set the maximum allowable number of
HTTP sessions. The value must be in the range of (0 to 16). The default value is 16. The currently
configured value is shown when the web page is displayed.

Command Buttons

Submit - Send the updated screen to the switch. Changes take effect on the switch but these
changes will not be retained across a power cycle unless a save is performed.