Fortinet 548B User Manual

Page 684

Advertising
background image

- 684 -

Broadcast Poll Interval - Specifies the number of seconds between broadcast poll requests
expressed as a power of two when configured in broadcast mode. Broadcasts received prior to the
expiry of this interval are discarded. Allowed range is (6 to 10). Default value is 6.

Multicast Poll Interval - Specifies the number of seconds between multicast poll requests
expressed as a power of two when configured in multicast mode. Multicasts received prior to the
expiry of this interval are discarded. Allowed range is (6 to 10). Default value is 6.

Unicast Poll Timeout - Specifies the number of seconds to wait for an SNTP response when
configured in unicast mode. Allowed range is (1 to 30). Default value is 5.

Unicast Poll Retry - Specifies the number of times to retry a request to an SNTP server after the
first time-out before attempting to use the next configured server when configured in unicast mode.
Allowed range is (0 to 10). Default value is 1.

Command Buttons

Submit - Sends the updated configuration to the switch. Configuration changes take effect
immediately.

11.2.13.2 Viewing SNTP Global Status Page

Non-Configurable Data

Version - Specifies the SNTP Version the client supports.

Supported Mode - Specifies the SNTP modes the client supports. Multiple modes may be
supported by a client.

Last Update Time - Specifies the local date and time (UTC) the SNTP client last updated the
system clock.

Last Attempt Time - Specifies the local date and time (UTC) of the last SNTP request or receipt of
an unsolicited message.