This command is used to set an IP address to be a filter.

Syntax

ip filter <ipaddr>
no ip filter <ipaddr>

<ipaddr> - Configure a IP address to the filter.

no - Remove this IP address from filter.

Default Setting

None

Command Mode

Global Config

7.3.2

Serial Interface Commands

7.3.2.1 show line console

This command displays serial communication settings for the switch.

Syntax

show line console

Default Setting

None

Command Mode

Privileged Exec

Display Message

Serial Port Login Timeout (minutes): Specifies the time, in minutes, of inactivity on a Serial port
connection, after which the Switch will close the connection. Any numeric value between 0 and 160
is allowed, the factory default is 5. A value of 0 disables the timeout.

Baud Rate: The default baud rate at which the serial port will try to connect. The available values are
1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200 bauds.

Character Size: The number of bits in a character. The number of bits is always 8.

Flow Control: Whether Hardware Flow-Control is enabled or disabled. Hardware Flow Control is
always disabled.

Stop Bits: The number of Stop bits per character. The number of Stop bits is always 1.

Parity: The Parity Method used on the Serial Port. The Parity Method is always None.