25 managing link state, 2 configuring link state status – Fortinet 548B User Manual

Page 780

Advertising
background image

- 780 -

11.3.25 Managing Link State

11.3.25.1 Configuring Link State Configuration Page

Selection Criteria

Admin Mode - Choose the link state administrative mode for the switch by selecting enable or
disable from the pull-down menu. The factory default is disabled.

Group ID

– You can use this screen to reconfigure an existing group or to create a new one. Use this

pull-down menu to select one of the existing groups or select 'Create' to add a new one.

Group Mode - Choose the group administrative mode for the switch by selecting enable or disable
from the pull-down menu. The factory default is disabled.

Upstream - Choose the upstream port for a group. Switch will monitor the link level of this port for
rapidly fail-over of redundant LAN ports.

Configurable Data

Downstream - Choose downstream ports for a group. Switch will associate these downstream ports
with upstream port. If the upstream port is link down, all downstream ports will be disabled.
Otherwise, they will be enabled.

Command Buttons

Submit - Update the switch with the values on this screen. If you want the switch to retain the new
values across a power cycle, you must perform a save.

Delete - Delete this group.

11.3.25.2 Configuring Link State Status

This page displays the status of all currently configured link state.

Advertising