22 managing lldp – Fortinet 548B User Manual

Page 764

Advertising
background image

- 764 -

11.3.22 Managing LLDP

11.3.22.1 Configuring LLDP Global Configuration Page

Configurable Data

Transmit Interval - Specifies the interval in seconds to transmit LLDP frames. The range is from (1
to 32768) . Default value is 30 seconds.

Transmit Delay - Specifies the transmit delay in seconds. The range is from (1 to 8192) . Default
value is 2 seconds.

Hold Multiplier - Specifies the multiplier on Transmit Interval to assign TTL. The range is from (2 to
10). Default value is 4.

Re-Initialization Delay - Specifies the delay before re-initialization. The range is from (1 to 10) .
Default value is 2 seconds.

Notification Interval - Specifies the interval in seconds for transmission of notifications. The range
is from (5 to 3600) . Default value is 5 seconds.

Command Buttons

Submit - Send the updated screen to the switch and cause the changes to take effect on the switch
but these changes will not be retained across a power cycle unless a save is performed.

Advertising