9300 Servo PLC

Appendix

3.5

System error messages

3−9

L

9300 Servo PLC EN 5.0

3.5.1

Overview of system error messages, error sources and responses

System error message

Possible settings/response
· Lenze setting ü setting possible

Available in

No.

Display

Source

Meaning

Code

TRIP

Message

Warning

FAIL−QS

P

Off

Drive

PLC

Servo

PLC

ECSxA

x011 OC1

MCTRL

Motor cable short circuit

·

ь

ь

x012 OC2

MCTRL

Motor cable earth fault

·

ь

ь

x015 OC5

MCTRL

I x t overload

·

ь

ь

x016 OC6

MCTRL

I

2

x t overload (C0120)

·

ь

ь

x017 OC7

MCTRL

I x t warning (C0123)

C0604

ь

·

ь

ь

x018 OC8

MCTRL

I

2

x t warning (C0127)

C0606

ь

·

ь

ь

ь

x020 OU

MCTRL

Overvoltage in the DC bus

·

ь

ь

x030 LU

MCTRL

Undervoltage in the DC bus

·

ь

ь

x032 LP1

MCTRL

Motor phase failure

C0597

ь

ь

·

ь

ь

x050 OH

MCTRL

Heatsink temperature higher than fixed limit
temperature

·

ь

ь

x051 OH1

MCTRL

Temperature inside the controller > 90° C

·

ü

x053 OH3

MCTRL

Motor temperature higher than fixed limit
temperature

C0583

·

ь

ь

ь

x054 OH4

MCTRL

Heatsink temperature higher than variable limit
temperature (C0122)

C0582

·

ь

ь

ь

x055 OH5

MCTRL

Temperature inside the controller > C0124

C0605

ь

·

ь

ь

x057 OH7

MCTRL

Motor temperature higher than variable limit
temperature (C0121)

C0584

·

ь

ь

ь

x058 OH8

MCTRL

Motor temperature via inputs T1/T2 too high

C0585

ь

ь

·

ь

ь

x061 CE0

AIF

Communication error in AIF module

óPLC

C0126

ь

ь

·

ь

ь

ь

CAN communication error:

x062 CE1

CAN1

CAN1_IN (monitoring time can be set under
C0357/1)

C0591

ь

ь

·

ь

ь

ь

x063 CE2

CAN2

CAN2_IN (monitoring time can be set under
C0357/2)

C0592

x064 CE3

CAN3

CAN3_IN (monitoring time can be set under
C0357/3)

C0593

x065 CE4

CAN

CAN BUS−OFF status
(too many faulty telegrams have been received)

C0595

ь

ь

·

ь

ь

ь

x066 CE5

CAN

CAN time−out (gateway function C0370)

C0603

ь

ь

·

ь

ь

ь

x070 U15

Internal

Undervoltage of internal 15 V voltage supply

·

ь

ь

ь

x071 CCr

Internal

Internal fault

1)

·

ь

ь

ь

x072 PR1

Internal

Check sum error in parameter set 1

·

ь

ь

ь

x074 PEr

Internal

Program error

1)

·

ь

ь

ь

x075 PR0

Internal

General error in parameter sets

1)

·

ь

ь

ь

x079 PI

Internal

Error during parameter initialisation

1)

·

ь

ь

ь

x080 PR6

Internal

Too many user codes

·

ь

ь

ь

x082 Sd2

MCTRL

Resolver error

C0586

·

ь

ь

ь

ь

x083 Sd3

MCTRL

Encoder error at X9 PIN 8

C0587

ь

ь

·

ь

x085 Sd5

MCTRL

Encoder error at analog input (X6) (C0034 = 1)

C0598

ь

ь

·

ь

ь

x086 Sd6

MCTRL

Sensor error: motor temperature (X7 or X8)

C0594

·

ь

ь

ь

ь

x087 Sd7

MCTRL

Absolute value encoder error at X8

1)

C0025

·

ь

ь

x088 Sd8

MCTRL

Absolute value encoder error at X8

1)

C0580

ь

·

ь

ь

x: 0 = TRIP, 1 = Message, 2 = Warning, 3 = FAIL−QSP

1)

When the error has been eliminated: Deenergise the controller completely!