Inputs_mctrl, 9300 servo plc, System blocks – Lenze Drive PLC Developer Studio 9300 Servo PLC (V8.x) User Manual

Page 59: 1 inputs_mctrl, System variables

Advertising
background image

9300 Servo PLC

System blocks

2.12

MCTRL_MotorControl (node number 131)

2−45

L

9300 Servo PLC EN 5.0

The process image is created in the course of a fixed system task (interval: 1 ms).

·

Exception: MCTRL_bActTPReceived_b, MCTRL_dnActIncLastScan_p and MCTRL_nNAct_v
are read into the process input image of the task in which they are actually used.

2.12.1

Inputs_MCTRL

System variables

Variable

Data type

Signal type

Address

Display

Code

Display

Format

Note

MCTRL_bQspIn_b

Bool

Binary

%IX131.0.0.

0

C0042

bin

TRUE = Drive carries out quick stop
(QSP)

MCTRL_nNSetIn_a

Integer

Analog

%IW131.1

C0050

dec [%]

Speed setpoint

·

16384

º 100 % n

max

(C0011)

MCTRL_bMMax_b

Bool

Binary

%IX131.0.2

TRUE = Speed controller operates
within the limits.

MCTRL_nMSetIn_a

Integer

Analog

%IW131.3

C0056

dec [%]

Torque setpoint

·

16384

º 100 % M

max

(C0057)

MCTRL_bIMax_b

Bool

Binary

%IX131.0.1

TRUE = Drive operates at current limit
C0022

MCTRL_nIAct_a

Integer

Analog

%IW131.5

Actual motor current

·

16384

º 100 % I

max

(C0022)

MCTRL_nDCVolt_a

%IW131.6

DC voltage

·

16384

º 1000 V

MCTRL_nMAct_a

%IW131.4

Actual torque

·

16384

º 100 % M

max

(C0057)

MCTRL_wMmaxC57

Word

%IW131.16

Display of maximum torque
(C0057) x 10

MCTRL_bUndervoltage_b

Bool

Binary

%IX131.0.3

Monitoring: Undervoltage

MCTRL_bOvervoltage_b

%IX131.0.4

Monitoring: Overvoltage

MCTRL_bShortCiruit_b

%IX131.0.5

Monitoring: Short circuit

MCTRL_bEarthFault_b

%IX131.0.6

Monitoring: Earth fault

MCTRL_bIxtOverload_b

%IX131.9.2

Monitoring: I x t overload

MCTRL_bSpeedLoop
Fault_b

%IX131.9.4

Monitoring: Speed out of tolerance
margin

MCTRL_nPos_a

Integer

Analog

%IW131.7

Actual phase value as an analog signal

·

90°

º 100%

MCTRL_nNAct_v

Integer

Velocity

%IW131.8

Actual speed value [inc/ms]

MCTRL_nNAct_a

Integer

Analog

%IW131.2

Actual speed value

·

16384

º 100 % n

max

(C0011)

MCTRL_dnPos_p

Double
Integer

Position

%ID131.5

Rotor position of the motor

MCTRL_bNmaxFault_b

Bool

Binary

%IX131.0.7

Monitoring: Max. system speed
exceeded

MCTRL_nNmaxC11

Integer

%IW131.15

Display of max. speed (C0011)

MCTRL_bActTP
Received_b

Bool

Binary

%IX131.0.10

Receive touch probe (TP)

MCTRL_dnActIncLast
Scan_p

Double
Integer

Position

%ID131.6

Dinc between TP and task start