3.6

Code table

9300 Servo PLC

Appendix

3−34

L

9300 Servo PLC EN 5.0

Code

Info

Possible settings

LCD

Code

Info

Selection

Lenze

LCD

C0206 Produkt date

g

Production date

C0207 DL info 1

g

Download info 1

C0208 DL info 2

g

Download info 2

C0209 DL info 3

g

Download info 3

C0250 FCODE 1Bit

0

Freely configurable code (digital signals)

·

FCODE_bC250_b

0

1

C0254 Vp angle CTRL

0.4000

Gain of angle controller (V

p

)

0.0000

{0.0001}

3.9999

C0300

Internal error diagnostics

C0301

Internal error diagnostics

C0302

Internal error diagnostics

C0350 CAN address

1

System bus: Node address

1

{1}

63

C0351 CAN baudrate

0

System bus: Baud rate

0

500 kbps

1

250 kbps

2

125 kbps

3

50 kbps

4

1000 kbps

5

20 kbps

C0352 CAN mst

0

System bus: Master/slave configuration of the PLC

·

With selection 1 or 2, the PLC sends a system bus
boot−up and is thus quasi" master.

·

Additional information about the "heartbeat" and "node
guarding" function can be found in the Manual for the
function library LenzeCanDSxDrv.lib.

0

Slave (boot−up not active)

1

Master (boot−up active)

2

Master with "node guarding"
(SyncReceived no longer possible)

3

Slave and "heartbeat" producer

4

Slave with "node guarding"

C0353 CAN addr sel

System bus: Source for PDO identifiers

0

Identifier assignment under C0350 + basic identifier

1

Identifier assignment under C0354/x

1

0

CAN1_IN/OUT

2

0

CAN2_IN/OUT

3

0

CAN3_IN/OUT

C0354 CAN addr

System bus: Definition of individual PDO identifiers

·

Value to be entered = Identifier − 384

1

{1}

512

1

129

CAN1_IN

2

1

CAN1_OUT

3

257

CAN2_IN

4

258

CAN2_OUT

5

385

CAN3_IN

6

386

CAN3_OUT