9300 servo plc, Appendix, 5 system error messages – Lenze Drive PLC Developer Studio 9300 Servo PLC (V8.x) User Manual

Page 113

Advertising
background image

9300 Servo PLC

Appendix

3.5

System error messages

3−11

L

9300 Servo PLC EN 5.0

System error message

Possible settings/response
· Lenze setting ü setting possible

Available in

No.

Display

Source

Meaning

Code

TRIP

Message

Warning

FAIL−QS

P

Off

Drive

PLC

Servo

PLC

ECSxA

Floating−point error (REAL) in:

x209 float Sys−T

Internal

System task

2)

·

ь

ь

ь

ь

ь

x210 float Cycl.−T

Cyclic task (PLC_PRG, ID 1)

x211 float T Id2

Task with ID 2

x212 float T Id3

Task with ID 3

x213 float T Id4

Task with ID 4

x214 float T Id5

Task with ID 5

x215 float T Id6

Task with ID 6

x216 float T Id7

Task with ID 7

x217 float T Id8

Task with ID 8

x218 float T Id9

Task with ID 9

x220 NoT−FktCredit

Internal

Not enough technology units available in the
PLC

·

ь

ь

ь

x230 No Program

Internal

No PLC program loaded in PLC

·

ь

ь

ь

x231 Unallowed Lib

Internal

A library function has been called in the PLC
program which is not supported

·

ь

ь

ь

x232 NoCamData

Internal

Motion profiles (cam data) are not available

·

ь

ь

ь

Free CAN objects:

x240 ovrTransQueue

Free CAN
obj.

Overflow of the transmit request memory

C0608

·

ь

ь

ь

3)

ь

ь

ь

ь

x241 ovr Receive

Too many receive telegrams

C0609

·

ь

ь

ь

Application memory (FLASH):

x250 2.Flash Err

Internal

Access not possible

1)

(FLASH memory defective or not available)

·

ü

x251 AddData CsErr

Internal

Check sum error occurred when loading data
into the FLASH memory

x252 AddData DlErr

Internal

Error occurred when downloading data into the
FLASH memory (e.g. time−out)

x260 Err NodeGuard

Node
guarding

"Life guarding event": The PLC as a CAN slave
has not received any "node guarding" telegram
within the node lifetime of the CAN master.

C0384

·

ь

ь

ь

3)

ь

ь

ь

ь

x: 0 = TRIP, 1 = Message, 2 = Warning, 3 = FAIL−QSP

1)

When the error has been eliminated: Deenergise the controller completely!

2)

In DDS adjustable under Project

W Exception response

3)

Only with 9300 Servo PLC!