Maximum speed, 9300 servo plc, System blocks – Lenze Drive PLC Developer Studio 9300 Servo PLC (V8.x) User Manual

Page 65: 6 maximum speed

Advertising
background image

9300 Servo PLC

System blocks

2.12

MCTRL_MotorControl (node number 131)

2−51

L

9300 Servo PLC EN 5.0

2.12.6

Maximum speed

The maximum speed (n

max

) is set under C0011. This value is used as a reference for the absolute and

relative setpoints selected for the acceleration and deceleration times and for the upper and lower
speed limits.

·

n

max

= 100 %

º

(INT) 16384

Code

LCD

Possible settings

Info

Lenze

Selection

C0011 Nmax

3000

Maximum speed
Reference value for the absolute and
relative setpoint selection for the
acceleration and deceleration times.

·

For parameterisation via interface:
Large changes in one step should
only be made when the controller
is inhibited.

500

{1 rpm}

16000

Tip!

MCTRL_nNmaxC11 displays the maximum speed set under C0011.

·

Use this system variable for programming your own speed scalings.

·

Example: C0011 = 3000 rpm

ð

MCTRL_nNmaxC11 = 3000

Advertising