9300 servo plc, System blocks – Lenze Drive PLC Developer Studio 9300 Servo PLC (V8.x) User Manual

Page 45

Advertising
background image

9300 Servo PLC

System blocks

2.8

DFIN_IO_DigitalFrequency (node number 21)

2−31

L

9300 Servo PLC EN 5.0

Transmission function

DFIN_nIn_v

+ f [Hz] @

60

Strichzahl aus C0425

@ 2

14

15000

Example:

·

Input frequency = 200 kHz

·

C0425 = 3, this corresponds to 2048 increments/rev.

DFIN_nIn_v [rpm]

+ 200000 Hz @ 60

2048

+ 5859 rpm

Signal adaptation

Finer resolutions can be achieved by adding a downstream FB (e.g. L_CONV from the
LenzeDrive.lib):

DF_IN

DFIN_bEncFaultCable_b

C0426

C0427

X9

C0425

4V

(X9/8)

1

0

E5

TP/MP

-Ctrl

C0428

C0429

MONIT_SD3

DFIN_nIn_v

DFIN_bTPReceived_b

DFIN_dnIncLastScan_p

NNumerator

Ndenominator

nIn_a

nOut_a

L_CONV

Fig. 2−16

Digital frequency input (DFIN_IO_DigitalFrequency) with downstream FB L_CONV for scaling

nOut_a

+ f [Hz] @

60

Strichzahl aus C0425

@ nNumerator

nDenominator

@ 2

14

15000