9300 servo plc, Appendix, 6 code table – Lenze Drive PLC Developer Studio 9300 Servo PLC (V8.x) User Manual

Page 137

Advertising
background image

9300 Servo PLC

Appendix

3.6

Code table

3−35

L

9300 Servo PLC EN 5.0

Code

Info

Possible settings

LCD

Code

Info

Selection

Lenze

LCD

C0355 CAN Id

g

System bus: PDO identifiers

385

{1}

896

1

CAN1_IN

2

CAN1_OUT

3

CAN2_IN

4

CAN2_OUT

5

CAN3_IN

6

CAN3_OUT

C0356 CAN boot up

System bus: Time settings

1

3000

0

{1 ms}

65000 Delay time after power−on for initialisation through the

quasi" master.

2

0

0

{1}

65000

0 = Event−controlled transmission

Task time factor for sending the CAN2_OUT process data
object.

3

0

Task time factor for sending the CAN3_OUT process data
object.

4

20

0

{1 ms}

65000 Delay time for sending the process data object.

C0357 CE monit time

System bus: Monitoring time for process data input objects

0

{1 ms}

65000

1

3000

CE1 monitoring time

2

3000

CE2 monitoring time

3

3000

CE3 monioring time

C0358 Reset node

0

System bus: Reset node

0

No function

1

CAN reset node

C0359 CAN state

g

System bus: Status

0

Operational

1

Pre−operational

2

Warning

3

Bus off

4

Stopped

C0360 CAN message

g

System bus: Telegram counter
(number of telegrams)

·

For values > 65535 counting restarts with 0

0

{1 ms}

65535

1

All sent (without free CAN objects)

2

All received (without free CAN objects)

3

Sent on CAN1_OUT

4

Sent on CAN2_OUT

5

Sent on CAN3_OUT

6

Sent on parameter data channel1

7

Sent on parameter data channel2

8

Received from CAN1_IN

9

Received from CAN2_IN

10

Received from CAN3_IN

11

Received from parameter data channel1

12

Received from parameter data channel2

Advertising