2.12.17.12 OH8 − motor temperature monitoring via T1, T2

This monitoring function protects the motor.

Error

Monitoring function

System variable

Possible responses

No.

Display

TRIP

Message

Warning

FAIL−QSP

Off

x058 OH8

Motor temperature (PTC)

MCTRL_bPtcOverTemp_b

ь

ь

·

· Lenze setting

ü Setting possible

MCTRL_bPTCOverTemp_b is derived from the digital signal across the terminals T1, T2 next to the
power terminals UVW.

·

The switch−off threshold and the hysteresis depend on the encoder system (DIN 44081).

·

The response is set under C0585:

Code

LCD

Possible settings

IMPORTANT

Lenze

Selection

C0585 MONIT OH8

3

Monitoring configuration: Motor
temperature
(Motor temperature across T1/T2 too
high)

·

Temperature monitoring via PTC
input

0

TRIP

2

Warning

3

Off

Stop!

If you use the inputs T1, T2 to protect the motor, the monitoring response should not be "Warning"
or "Off" since the motor could be damaged or destroyed in the event of more overload!