Aif2_io_automationinterface (node number 42), Inputs_aif2, 9300 servo plc – Lenze Drive PLC Developer Studio 9300 Servo PLC (V8.x) User Manual

Page 21: System blocks, 1 inputs_aif2, 2 aif2_io_automationinterface (node number 42)

Advertising
background image

9300 Servo PLC

System blocks

2.2

AIF2_IO_AutomationInterface (node number 42)

2−7

L

9300 Servo PLC EN 5.0

2.2

AIF2_IO_AutomationInterface (node number 42)

2.2.1

Inputs_AIF2

Automation interface (node number 42)

This SB is used as an interface for input signals (e.g. setpoints/actual values) from attached fieldbus
modules (e.g. INTERBUS, PROFIBUS−DP).

·

The process image is
– created in the cyclic task in a fixed time interval of 10 ms.
– created in an interval task within the time set for this task.
– read at the beginning of the task and written at its end.

Tip!

Please observe the Operating Instructions for the attached fieldbus module.

Inputs_AIF2

Automation

Interface

AIF2_bInB0_b

AIF2_bInB15_b

AIF2_nInW1_a

16 Bit

...

16 binary

signals

Byte

1

Byte

2

Byte

3

Byte

4

Byte

5

Byte

6

Byte

7

Byte

8

AIF2_bInB16_b

AIF2_bInB31_b

AIF2_nInW2_a

16 Bit

...

16 binary

signals

16 Bit

LowWord

16 Bit

HighWord

AIF2_nInW3_a

AIF2_dnInD1_p

16 Bit

16 Bit

AIF2_nInW4_a

Fig. 2−3

Inputs_AIF2

Advertising