9300 Servo PLC

Appendix

3−18

L

9300 Servo PLC EN 5.0

Fault reset

The current fault can be reset by a TRIP−RESET e.g. via C0043:

Code

LCD

Possible settings

Info

Lenze

Selection

C0043 Trip reset

0

TRIP reset

0

TRIP−RESET (current TRIP reset)

1

Error occurred (TRIP is active)

Deleting entries in the fault memory

The entries in the fault memory can be deleted via C0167.

·

This function can only be used if there is no active fault.

Code

LCD

Possible settings

Info

Lenze

Selection

C0167 Reset failmem

0

Reset fault memory

0

No function

1

Delete all entries in history buffer

Access to fault memory via Global Drive Control (GDC)

The fault memory of the PLC can also be displayed in the GDC.

·

Double−click on "Dialog diagnostics" in the GDC parameter menu to open the 9300
diagnostics dialog box:

History buffer

 ‚ ƒ

 No. of system error message and response (C0168/x)
‚ Time of occurrence (C0169/x)
ƒ Frequency of successive occurrence (C0170/x)
„ Reset of the fault (TRIP−RESET); only possible if there is no active fault.

„