J52 Box Out

Models FlexTest® IIm/GT/SE Controller Hardware

FlexTest SE Controller Connections

235

J52 Box Out

Connector J52 Box Out allows the Model 493.02 Chassis to send clock,
hydraulic, and interlock signals to another Model 493.02 Chassis.

Jumper plug required

If connector J52 Box Out is not used, you must install a jumper plug to maintain
the integrity of the interlocks. Use jumper plug PN 100-057-246 or jumper pins:
2-10, 3-11, 4-12, 5-13, 6-14, 7-15.

J52 Connector Pin Assignments

P

IN

N

AME

F

UNCTION

1

+clk in

+External clock output

2

hyd high out

Hydraulic high output

3

reset out

Interlock reset request output

4

ground

Signal ground

5

/intlk out

Hydraulic interlock output

6

hyd low out

Hydraulic low output

7

ground

Signal ground

8

N/C

No connection

9

- clk out

- External clock output

10

hyd hi return in

Hydraulic high return input

11

reset return in

Interlock reset return input

12

signal return

Signal return for optically isolated inputs

13

/intlk return in

Hydraulic interlock return input

14

hyd low return in

Hydraulic low return input

15

signal return

Signal return for optically isolated inputs