J25 diagram – MTS Model FlexTest SE User Manual

Page 132

Advertising
background image

Models FlexTest® IIm/GT/SE Controller Hardware

J25 Hydraulic Power Unit Connection

FlexTest GT Controller Connections

132

J25 Diagram

To/From

HPU

9

10

11

12

1

2

3

4

5

6

7

8

Controller 24 Vdc

J25

To/From

Chassis

To J24 pin 13

To J29 pin 8

E-stop

HPS On

Sense

HPS 24 Vdc

Start

Lo

High

Over Temp

Low Level

+24

vdc

CRM

Motor

Relay

SOL

CRM

+24 Vdc

1CR

Start

Relay

Hi Pressure

Solenoid

HPS Interlock

Relay

HPS Defeat Voltage

(not connected in HPS)

Advertising
This manual is related to the following products: