J25 Hydraulic Power Unit Connection

Models FlexTest® IIm/GT/SE Controller Hardware

FlexTest GT Controller Connections

133

System I/O

Connector J54 Sys I/O provides three digital inputs and one digital output. The
inputs are connected to the high and low inputs of an opto-isolator. The output is
from the collector (+) and emitter (-). For circuit drawings, see the

“Digital I/O

Connections”

on page 141.

Cable specification

J54 Sys I/O is a 15-contact type D female connector.

15-contact type D male EMI connector.

Backshell–EMI metallized plastic.

Cable–24 AWG 4 connector with overall foil shield, (Belden 9534 or
equivalent) with drain wire connected to metallized plastic backshell at the
chassis and to ground at the emergency stop station.

+

-

+

-

+

-

+

-

+24 V

+24 V

+24 V

Input 1

Output 1

Input 3

Input 2

To/From

External

Devices

1
2
3
4
5
6
7
8
9

10

11

12
13
14
15

J54